15% OFFPolycab
POLYCAB H.T. XLPE Cable A2XFY 3 Core 300 sq mm 3.3kV (UE) / 6.6kV (E)
Size: 6.6 KV (UE)/ 11 KV (E)
₹6,005₹7,065
Exclusive of GST · GST invoice provided on request
● In Stock (1000)
1
The POLYCAB H.T. XLPE Cable A2XFY 3×300 sq mm 3.3kV (UE) / 6.6kV (E) is designed for suitable medium-voltage power distribution, industrial electrical installations, substations, infrastructure projects and fixed electrical networks.
This cable features a 3-core configuration with 300 sq mm aluminium conductors per core, along with XLPE insulation and armoured construction. The A2XFY cable design is intended for suitable medium-voltage power distribution applications where electrical insulation, reliable power transmission and mechanical protection are required.
Technical Details
- Brand: POLYCAB
- Product Type: H.T. / Medium-Voltage XLPE Power Cable
- Cable Designation: A2XFY
- Number of Cores: 3 Core
- Conductor Size: 300 sq mm per core
- Cable Configuration: 3 × 300 sq mm
- Conductor Material: Aluminium
- Insulation: XLPE (Cross-Linked Polyethylene)
- Voltage Designation: 3.3kV (UE) / 6.6kV (E)
- Voltage Category: Medium Voltage / High Tension
- Cable Construction: A2XFY
- Armouring: Armoured construction
- Outer Sheath: Protective outer sheath
- Conductor Construction: Stranded aluminium conductor
- Application: Medium-voltage power distribution
- Installation: Fixed installations, subject to manufacturer's specifications
- Insulation Type: XLPE
- Mechanical Protection: Armoured construction provides additional mechanical protection
- Typical Applications: Industrial plants, substations, infrastructure and electrical distribution networks
- Current Carrying Capacity: Confirm from the manufacturer's ampacity tables based on installation conditions
- Short-Circuit Rating: Confirm from the product-specific POLYCAB technical datasheet
- Overall Diameter: Confirm from the product-specific datasheet
- Cable Weight: Confirm from the product-specific datasheet
- Minimum Bending Radius: Confirm according to manufacturer's installation guidelines
- Operating Temperature: Confirm from the specific POLYCAB technical datasheet
- Voltage Drop: Depends on cable length, load current, conductor characteristics and installation conditions
- HSN Code: Verify the applicable HSN classification before invoicing
#polycab ht xlpe cable#polycab h.t. xlpe cable#polycab a2xfy cable#polycab 3 core 300 sq mm cable#polycab 3×300 sq mm cable#polycab 300 sq mm xlpe cable#polycab 3.3kv xlpe cable#polycab 6.6kv xlpe cable
Need bulk pricing or installation? Call 93569 13565 or send an enquiry.